Anaesthesia Ventilator-manufacture,factory,supplier from China

(Total 24 Products for Anaesthesia Ventilator)
Product Description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations. During first aid and transport, even in the event of a power outage, it can help patients maintain normal respiratory function and prevent dangerous situationscaused by insufficient oxygen.FAQQ1.What are your packaging details?A1.
Contact Now
Product description This transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contact Now
Product description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations.
Contact Now
Product descriptionBuilt in 8'' color anaesthesia ventilatorNew compact CO2 absorber(autoclavable,Patent)high end precise vaporizer(volume>280ml,Patent)Battery back up for all system over 60 mins,bain circuit interfaceOptional:Touch screen anaesthesia ventilatorOptional:Anaesthesia gas scavenging systemOptional:Yoke system,electronic tidal volume(Innovation)Optional:Continuous FIO2 monitoring, EtCO2 monitoring functionOptional:Built-in air compressor or Air/O2 inter-link system(innovation)Technical ParameterProduct nameModel no. MOQ Q'ty MeasurementG.W.
Contact Now
Product descriptionWOWO200 anesthesia ventilator is an very exellent machine.lt has many ventilation mode, waveform display, parameters setting and parameters alarm.lt can match different anesthesia machine. After using WOWO200 anesthesia ventilator, the feedback of hospitals is very exellent.FAQQ1. How long is the warranty period?A1.24 months.Q2.What is the payment method?A2.TT, L/C, etc.Q3.When will you deliver the goods?A3.Usually 7-30 days.Q4.
Contact Now
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
Contact Now
IntroductionAnaesthesia main unit:High resolution 5.5''  LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
Contact Now
Product descriptionAnaesthesia main unit:High luminance digital LED screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarm: O2 gas pressure is low, alarm time exceeds 7 secondsHigh pressure limit: Whenever the airway pressure exceeds the preset high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Power failure alarming,power extendable functionO2 flush:25~75L/minGas Pressure:O2:0.3~0.5MPaPower:220V±10%, 50Hz±1%Technology specificationFlow meter:O2 - dual tube(0.05~1L/min,1.1~10L/min
Contact Now
Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contact Now
Product descriptionThe anesthesia evaporator combines the characteristics of ergonomics, accuracy, safety, and reliability. Precision design will provide reliable and safe solutions for the filling and installation types of anesthesia machines.Adopting the latest innovative design of the conveying system, the vaporizer can deliver accurate concentrations under different flow rates, pressures, temperatures, and other conditions.The carburetor is calibrated by skilled technicians.
Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contact Now
Product DescriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionSD-M2000A(P) Veterinary anesthesia machines are reliable professional equipment for small animal anesthesia. Easy installation and maintenance, saving space.
Contact Now
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15-year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
Contact Now
Product descriptionThis endoscope camera is equipped with Sony CCD sensors, focusing on high-quality images with a large number of pixels, low noise, and excellent photosensitivity. Its compact design helps users easily carry it for emergency situations or basic OPD use.
Contact Now
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
Contact Now
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
Contact Now
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasisBLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaponzation of prostatic tissue or any fat tissue.
Contact Now
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
Contact Now
Relate News
Anaesthesia Machine MODEL40Built in 8"color anaesthesia ventilatorNew compact CO2 absorber (autoclavable, Patent)High end precise vaporizer (Volume > 280ml, Patent) Battery back up for all system over 60 mins, bain circuit interfaceOptional: Touch screen anaesthesia ventilatorOptional: Anaesthesia gas scavenging systemOptional: Electronic anaesthesia vaporizer (Patent)Optional: Yoke system, Electronic tidal volume (Innovation)Optional: Continuous FIO2 monitoring, EtCO2 monitoring functionOptional: Built-in air compressor Or Air / O2 inter-link system (lnnovation)
SD-M2000B Anaesthesia MachineCompact design, save space in O.R.or Laboratory RoomBuilt in 5.5”LCD Anaesthesia ventilatorNew compact CO2 absorber (autoclavable, Patent)High precise big volume vaporizerOptional: Bain circuit interface, Continuous FIO2 monitoringOptional: Battery back up for all system not less than 60 mins
Anaesthesia Machine MODEL50High resolution 5.5" LCD screenClose, semi-close, semiopen systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressureventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.Low pressure protection: Once O2 pressure less than 0.1MPa, N2O gas supply was stopped automatically.Power failure alarming, power extendable functionO2 flush: 25~ 75 L/minGas Press
Can a Ventilator on Anesthesia Replace a Dedicated Ventilator?After the outbreak of the epidemic abroad in March this year, the demand for ventilators increased significantly. Faced with a large demand from abroad, domestic respirator manufacturers have reached saturation in production capacity but still cannot meet the strong demand. So much so that many people pay attention to anesthesia machines, which are also equipped with ventilators and have similar breathing patterns. Can anesthesia machines replace ventilators?
HUIFA has attended 87th CMEF - Shanghai, details as following fyi:Fair Name: The 87th China International Medical Equipment Fair (CMEF) Time: May.14  - May.17 Place: Shanghai, China Venue: Shanghai Convention & Exhibition centerMain Display Product:  Anaesthesia machine, Ventilator, Electrosurgical unit etc. Booth no.:  3Y09Website: https://www.cmef.com.cn/g1225.aspx Welcome to be our honored partners.HUIFA
Ventilator Gas Switching Mode    Different types of ventilators have different ways of converting the inspiratory phase and the expiratory phase. At present, there are mainly four forms of breathing phase switching in ventilators, the most basic of which are pressure switching and volume switching.    1. Time switching.     Negative pressure ventilators use time switching. Modern time-switched ventilators are controlled by electronic circuits.
Model30 Anesthesia MachineBuilt in 5.5" anaesthesia ventilator, bain circuit interfaceHigh end precise vaporizer (Volume > 280ml, Patent)New compact CO2 absorber (autoclavable, Patent)Battery back up for all system over 60 minsHigh brightness LED lighting systemOptional: Anaesthesia gas scavenging systemOptional: Electronic anaesthesia vaporizer (Patent)Optional: Yoke system, Electronic tidal volume (lnnovation)Optional: Continuous FIO2 monitoring, EtCO2 monitoring functionOptional: Built-in air compressor Or Air/O2 inter-link system (lnnovation)
Characteristics of Emergency Transport Ventilator      Many people believe that emergency transport ventilators are equivalent to simple ventilators, because compared to professional ICU therapeutic ventilators, emergency transport ventilators do not have as many ventilation modes and parameter monitoring in terms of mode function. However, in fact, professional emergency transport ventilators should have the following major characteristics (which cannot be achieved by large ICU ventilators):       Portability:1. Small in size and light in weight.
HUIFA & MEDEVO - Our main exhibition products:- Anesthesia machine & ventilator- Argon ESU, ESU, LEEP ESUFair Name: Arab Health 2025Time: 27th Jan. - 30th Jan., 2025Place: Dubai World Trade CentreBooth No.: Za'abeel Hall 7, M36Ahttp://www.arabhealthonline.comThank you for your kind visit on us.HUIFA & MEDEVO
HUIFA & MEDEVO - Our main exhibition products:- Anesthesia machine & ventilator- Argon ESU, ESU, LEEP ESUFair Name: The 91st China International Medical Equipment Fair (CMEF) Time: 8-11 April, 2025 Place: Shanghai, China Venue: National Exhibition & Convention Center Stand no.: HALL8.2 X48 Website: https://www.cmef.com.cn/g1225.aspx Welcome you visit us at your convenience.HUIFA
x

Submitted successfully

We will contact you as soon as possible

Close