CM-350Ar Electrosurgical Unit-manufacture,factory,supplier from China

(Total 24 Products for CM-350Ar Electrosurgical Unit)
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
  Contact Now
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
  Contact Now
CM-350A meets the surgeon's needs in the wide range of general procedures and in special ties including Gynecology, Urology, Neurology, Thorasic, plastic and Reconstructive surgery. It has spray coagulation which rivals the best spark gap generators and with minimum cutting effect.
  Contact Now
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, APG type ordinary equipment, powered by 220V±10% network power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues. It has the functions of unipolar pure cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation There are six working modes: , sof
  Contact Now
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
  Contact Now
Product descriptionLigasure is also called high frequency surgical system, and ligasure is widely used in various surgical operations. Compared with traditional electrosurgical equipment, ligasure has the function of cutting blood coagulation and sealing 7 mm large blood vessels.FAQQ1. What is the advantage about your company?A1.The company has been engaged in export business for more than 15 years, with a professional team and professional production line.Q2.
  Contact Now
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
  Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPure Cut: High-frequency alternating current produces smooth, fast cuts that induce little-understood hemostasis Mix 1: Preset Mix Cut Modes provide surgeons with varying degrees of hemostasis in cut mode. Mix 2: This mode is used for vaporization of prostate tissue or any fatty tissue. Higher output wattage gives rapid tissue cutting effect.
  Contact Now
Product descriptionThe 416KHz (±10%) high frequency current generated by the machine can be used for biological tissue cutting, coagulation and other surgical operations, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; Unipolar solidification: spray solidification, soft solidification and standard bipolar six working modes.
  Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasisBLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaponzation of prostatic tissue or any fat tissue.
  Contact Now
Product descriptionThe 416KHz (± 10%) high frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut 1, blend cut 2; Monopolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independent and isolated CF type anti-defibrillation application parts (Monopolar and Bipolar), Non-AP、Non-APG type common equipment, and 220V ± 10% or 110V ± 10% network power supply.Technology parameterRated out
  Contact Now
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type defibrillation-proof application parts (unipolar and bipolar), non-AP, APG-type common equipment, 220V±10% mains power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation on biological tissues.
  Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
  Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
  Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
  Contact Now
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
  Contact Now
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
  Contact Now
IntroductionAnaesthesia main unit:High resolution 5.5''  LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
  Contact Now
Product descriptionThe anesthesia evaporator combines the characteristics of ergonomics, accuracy, safety, and reliability. Precision design will provide reliable and safe solutions for the filling and installation types of anesthesia machines.Adopting the latest innovative design of the conveying system, the vaporizer can deliver accurate concentrations under different flow rates, pressures, temperatures, and other conditions.The carburetor is calibrated by skilled technicians.
  Contact Now
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
  Contact Now
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
  Contact Now
Product descriptionThis endoscope camera is equipped with Sony CCD sensors, focusing on high-quality images with a large number of pixels, low noise, and excellent photosensitivity. Its compact design helps users easily carry it for emergency situations or basic OPD use.
  Contact Now
Product descriptionApplied in all fields, such as laparoscopy, urology, rectoscopy, otolaryngology, etc1) It is recommended that all rigid and flexible mirrors can be used for diagnosis and surgery2) Combine Sony CMOS high-definition camera with 80W LED light source.3) Equipped with 22 inch high-definition display4) The integrated design of LED cold light source and camera saves space and is convenient to carry;5) Video recording and capture functionsTechnical specificationProduct ModelYKD-9122Camera1/2.8 inch SONY CMOS HD CameraPixels2,100,000 PixelsImage Size(Horizontal*Vertical)1920*10
  Contact Now
Product descriptionThe smoke evacuator is easy to operate and easy to replace filters.
  Contact Now
Relate News
CM-350C Electrosurgical UnitUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring (REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality de
CM-350ATechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeOutput modesa) Pure Cut:1W-350W(Max.400W,Load 500Ω) b)Blend 1:1W-250W(Load 500Ω)c)Blend 2:1W-200W(Load 500Ω)d) Blend 3:1W-150W(Load 500Ω)e)ENDO Cut:99%(Load 500Ω)f)Spray Coag.:1W-80W (Load 500Ω)g) Force Coag.:1W-120W (load 500 Ω)h) Desicate Coag.:1W-120W (Load 500Ω)i)BI-Coag:1W-70W (Load 100Ω)j)Auto-Coag.:1W-70W (Load 1
Is Oral and Dental Electrosurgical Unit Specialized?Electrosurgical Unit are widely used in general surgery, cosmetic plastic surgery, and various minimally invasive surgeries due to their excellent cutting and coagulation abilities.
ApplicationApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery,ENT surgery and etc.Pure cut: A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasis.Blend 1: Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.Blend 2: The mode is used for vaporization of prostatic tissu or any fat tissue.
ApplicationApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgerymicrosurgery, ENT surgery and etc.CUT MODEPURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasis.BLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaporization of prostatic tissue or any fat tissue.
Explanation of precautions when using electrosurgical unitElectrosurgical Unit is a device that almost every surgeon will come into contact with. When using it, the following points should be noted:1. Have an understanding of the principles of ESU cutting and coagulation.2. When using a electrosurgical unit, do not select the wrong mode. For example, do not choose the cutting and coagulation modes incorrectly. If you choose the cutting mode during coagulation, it will cause tissue cells to burn and die.3.
Application of Electrosurgical Unit in Oral Tissue Repair      Electrosurgical Unit is the use of high-frequency alternating current technology to generate thermal effects within tissues and selectively destroy certain tissues. The radio frequency energy emitted by the host is concentrated in the electrodes, forming a complete circuit through the human body, reflux plate, and its circuit. According to different usage purposes, energy output can be divided into fully rectified output and partially rectified output.
                                                                                                  Render Medical Group CM-350A (Leep)"Leep knife" is not actually a knife, why is it called "Leep knife"? In fact, the "Leep" is Loop Electrosurgical Exception Procedure, which means cervical circular resection.
Introduction to Electrosurgical UnitWhat is a ESU?Electrosurgical Unit is widely used in various surgeries, for tissue cutting and coagulation, and is one of the essential equipment in the operating room.What do the parameters of ESU mean?Electrosurgical Units are divided into monopolar and bipolar modes, and in monopolar mode, they must be used together with the negative electrode plate (neutral electrode plate). Let the current released by the blade flow back to the electric knife through the negative electrode plate to form a closed loop, so as not to burn the human body.
The Difference between Electrosurgical Unit and Ultrasonic KnifeThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ The mechanical oscillation of m amplitude generates fri