economical Anesthesia-manufacture,factory,supplier from China

(Total 24 Products for economical Anesthesia)
Product descriptionWOWO200 anesthesia ventilator is an very exellent machine.lt has many ventilation mode, waveform display, parameters setting and parameters alarm.lt can match different anesthesia machine. After using WOWO200 anesthesia ventilator, the feedback of hospitals is very exellent.FAQQ1. How long is the warranty period?A1.24 months.Q2.What is the payment method?A2.TT, L/C, etc.Q3.When will you deliver the goods?A3.Usually 7-30 days.Q4.
  Contact Now
Product descriptionSD-M2000A(P) Veterinary anesthesia machines are reliable professional equipment for small animal anesthesia. Easy installation and maintenance, saving space.
  Contact Now
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
  Contact Now
Product DescriptionVeterinary anesthesia systems are widely used in veterinary clinics, hospitals and laboratories and continue to be well received by customers around the world.The SD-M2000A(P) model is designed for safe, simple, and controlled inhalation anesthesia in animals. Veterinary anesthesia systems provide rapid control of depth of anesthesia, low respiratory resistance, acuity from high to low, simple to complex cases, small to large animals such as dogs, cats, rabbits, mice, birds, etc.Technical SpecificationAnaesthesia main unit:Working Mode: ManualWorking method: Close,
  Contact Now
Product Description1. 7" screen displays information area, alarm area, monitoring area, and setting area. 2. High precision mechanical flowmeter, instantly know the fresh gas flow to animals. 3. Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime. 4. Real time pressure-time, flow-time oscillogram 5. Manual and mechanical ventilation for safer operation.6. External sensor design makes parameters setting more accurate. 7.
  Contact Now
Product DescriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
  Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
  Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15-year history of developing anesthesia solutions to meet your needs.
  Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
  Contact Now
Product descriptionSD-M2000A(P) Veterinary anesthesia machines are reliable professional equipment for small animal anesthesia. Easy installation and maintenance, saving space.
  Contact Now
Product descriptionThe anesthesia evaporator combines the characteristics of ergonomics, accuracy, safety, and reliability. Precision design will provide reliable and safe solutions for the filling and installation types of anesthesia machines.Adopting the latest innovative design of the conveying system, the vaporizer can deliver accurate concentrations under different flow rates, pressures, temperatures, and other conditions.The carburetor is calibrated by skilled technicians.
  Contact Now
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
  Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
  Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
  Contact Now
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
  Contact Now
Product descriptionThis endoscope camera is equipped with Sony CCD sensors, focusing on high-quality images with a large number of pixels, low noise, and excellent photosensitivity. Its compact design helps users easily carry it for emergency situations or basic OPD use.
  Contact Now
Product DescriptionScope of ApplicationIt is suitable for various surgeries on cutting or coagulation, including general surgery, heart, urology, gynecology, anorectal surgery, orthopedics, thoracic surgery, tumor, etc. It is also used with surgeries of endoscope, hysteroscope, laparoscope, ENT endoscope, etc. The bipolar can be used in the fine surgeries of microsurgery, neurology, ENT and ophthalmology, hand surgery,etc.Product Details●Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
  Contact Now
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
  Contact Now
Product descriptionRemote fault diagnosis.Human voice alarm function.Full-function automatic power compensation.System has return electrode monitoring (REM) system.Microprocessor control and digital display in LED panel.Used for Monopolar and Bipolar surgery in many surgical fields.Support bipolar closure and separation to meet the requirements of surcical bipolar treatment withoutsticking the negative plate.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.This machine has a power-off protection circuit, which
  Contact Now
Product descriptionA high-brightness lighting device composed of high-power LED and its componentsThis product uses 80W LED as the light source. High luminous efficiency and high illumination.It is designed with a touch switch, brightness display, and electromagnetic compatibility switch power supply.Application: Hysteroscopy, Nasal Endoscopy, OtolaryngologyTechnical ParametersRated input power: 100WOptical output illumination value: >1600000LXLamp rated power: 80WColor temperature: 3000K-7000KColor rendering index: ≥90Lamp working life: ≥40000hTotal light: ≥500LmFAQQ1.
  Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPure Cut: High-frequency alternating current produces smooth, fast cuts that induce little-understood hemostasis Mix 1: Preset Mix Cut Modes provide surgeons with varying degrees of hemostasis in cut mode. Mix 2: This mode is used for vaporization of prostate tissue or any fatty tissue. Higher output wattage gives rapid tissue cutting effect.
  Contact Now
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
  Contact Now
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
  Contact Now
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
  Contact Now
Relate News
The Lowest Priced Simple Anesthesia Machine     More and more hospitals are now able to perform general anesthesia surgery, and the essential equipment for general anesthesia surgery is anesthesia machines. For grassroots medical units, they will not carry out difficult surgeries. At present, small surgeries with lower difficulty are mainly used, and the anesthesia time is relatively short with low risks. So these hospitals will not choose high priced multifunctional anesthesia machines or anesthesia workstations.
Overview of Anesthesia Machine       Anesthesiology is an important part of clinical medicine. Anesthesia machines are indispensable equipment for the implementation of anesthesia in clinical operations. With the continuous development of science and technology, new theories and new methods continue to emerge, the theory and practice of anesthesiology have also been greatly improved, and the structure and functions of anesthesia machines have also been completed day by day.
The Purpose of Anesthesia Machine     Theanesthesia machine is not only suitable for general anesthesia, but also can assist the breathing of critically ill patients during anesthesia. It can also be combined with other anesthetic drugs to perform compound anesthesia in different forms.(1) Definition and significance of anesthesia    The broad definition of anesthesia is to cause the patient to temporarily lose all or part of the pain sensation.
Application of Portable Anesthesia MachinePortable anesthesia machines are mainly used for outdoor operations, such as field operations, disaster relief, and emergency surgeries. Due to the different environments used, portable anesthesia machines and conventional anesthesia machines are more prominent and convenient to carry. Based on this principle, they are further expanded towards intelligent, integrated, and multifunctional aspects.The structure required for a portable anesthesia machine includes an anesthesia evaporator, respiratory support system, and respiratory circuit.
Anesthesia Machine Evaporator Application      Due to the application of highly efficient volatile inhalation anesthetics in anesthesia machines, the design of evaporators tends to be specialized, that is, based on the evaporation characteristics of a certain volatile inhalation anesthetic, an evaporator that is only used for that drug is calibrated. For example, specialized evaporators for halothane, methoxyflurane, enflurane, isoflurane, and sevoflurane.
MODEL30 Anesthesia MachineAnaesthesia main unit:High resolution 5.5" LCD screenClose, semi-close, semi-open systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.Low pressure protection: Once O2 pressure less than 0.1MPa, N2O qas supply was stopped automatically.Power failure alarming.
Structural Principle of Model 40 Anesthesia MachineThe  Model 40 anesthesia machine is a continuous airflow anesthesia system equipped with an air path that can transport air, oxygen, laughing gas, and inhaled anesthetic drugs. Two types of anesthetic drugs can be chosen: enflurane or isoflurane. The external input of oxygen and laughing gas should maintain a pressure of 0.4MPa ± 0.1MPa, and then enter the anesthesia machine through the gas transmission pipeline.
Introduction to Anesthesia Machine Evaporator      The anesthesia evaporator is an important component of the anesthesia machine, and its quality not only indicates the level of the anesthesia machine, but also relates to the success or failure of inhalation anesthesia, directly affecting the safety of the patient.
Can a Ventilator on Anesthesia Replace a Dedicated Ventilator?After the outbreak of the epidemic abroad in March this year, the demand for ventilators increased significantly. Faced with a large demand from abroad, domestic respirator manufacturers have reached saturation in production capacity but still cannot meet the strong demand. So much so that many people pay attention to anesthesia machines, which are also equipped with ventilators and have similar breathing patterns. Can anesthesia machines replace ventilators?
Anesthesia Machine EvaporatorThe Function of Evaporator Anesthesia machine evaporation tank, also known as evaporator, is generally divided into several types: enflurane, isoflurane, halothane, sevoflurane, desflurane, etc. The commonly used ones in China are enflurane tanks, isoflurane tanks, and sevoflurane, and the use of enflurane has been banned domestically. Its function is to convert liquid inhaled anesthetics into gas, and then mix them with oxygen to a certain proportion concentration before delivering them to the patient.