Electrocautery Unit-manufacture,factory,supplier from China

(Total 24 Products for Electrocautery Unit)
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
Contact Now
Product descriptionRemote fault diagnosis.Human voice alarm function.Full-function automatic power compensation.System has return electrode monitoring (REM) system.Microprocessor control and digital display in LED panel.Used for Monopolar and Bipolar surgery in many surgical fields.Support bipolar closure and separation to meet the requirements of surcical bipolar treatment withoutsticking the negative plate.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.This machine has a power-off protection circuit, which
Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPure Cut: High-frequency alternating current produces smooth, fast cuts that induce little-understood hemostasis Mix 1: Preset Mix Cut Modes provide surgeons with varying degrees of hemostasis in cut mode. Mix 2: This mode is used for vaporization of prostate tissue or any fatty tissue. Higher output wattage gives rapid tissue cutting effect.
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
Contact Now
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasisBLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaponzation of prostatic tissue or any fat tissue.
Contact Now
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type defibrillation-proof application parts (unipolar and bipolar), non-AP, APG-type common equipment, 220V±10% mains power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation on biological tissues.
Contact Now
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, APG type ordinary equipment, powered by 220V±10% network power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues. It has the functions of unipolar pure cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation There are six working modes: , sof
Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
Contact Now
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contact Now
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
Contact Now
Product descriptionLigasure is also called high frequency surgical system, and ligasure is widely used in various surgical operations. Compared with traditional electrosurgical equipment, ligasure has the function of cutting blood coagulation and sealing 7 mm large blood vessels.FAQQ1. What is the advantage about your company?A1.The company has been engaged in export business for more than 15 years, with a professional team and professional production line.Q2.
Contact Now
Product descriptionThis endoscope camera is equipped with Sony CCD sensors, focusing on high-quality images with a large number of pixels, low noise, and excellent photosensitivity. Its compact design helps users easily carry it for emergency situations or basic OPD use.
Contact Now
Product descriptionThe 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as biological tissue cutting and coagulation, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independently isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, non-APG type general equipment, 220V±10% or 110V±10% network power supply.Technology parameterRated out
Contact Now
CM-350A meets the surgeon's needs in the wide range of general procedures and in special ties including Gynecology, Urology, Neurology, Thorasic, plastic and Reconstructive surgery. It has spray coagulation which rivals the best spark gap generators and with minimum cutting effect.
Contact Now
Product Description1. 7" screen displays information area, alarm area, monitoring area, and setting area. 2. High precision mechanical flowmeter, instantly know the fresh gas flow to animals. 3. Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime. 4. Real time pressure-time, flow-time oscillogram 5. Manual and mechanical ventilation for safer operation.6. External sensor design makes parameters setting more accurate. 7.
Contact Now
Product descriptionBuilt in 8'' color anaesthesia ventilatorNew compact CO2 absorber(autoclavable,Patent)high end precise vaporizer(volume>280ml,Patent)Battery back up for all system over 60 mins,bain circuit interfaceOptional:Touch screen anaesthesia ventilatorOptional:Anaesthesia gas scavenging systemOptional:Yoke system,electronic tidal volume(Innovation)Optional:Continuous FIO2 monitoring, EtCO2 monitoring functionOptional:Built-in air compressor or Air/O2 inter-link system(innovation)Technical ParameterProduct nameModel no. MOQ Q'ty MeasurementG.W.
Contact Now
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
Contact Now
Product DescriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15-year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionWOWO200 anesthesia ventilator is an very exellent machine.lt has many ventilation mode, waveform display, parameters setting and parameters alarm.lt can match different anesthesia machine. After using WOWO200 anesthesia ventilator, the feedback of hospitals is very exellent.FAQQ1. How long is the warranty period?A1.24 months.Q2.What is the payment method?A2.TT, L/C, etc.Q3.When will you deliver the goods?A3.Usually 7-30 days.Q4.
Contact Now
Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contact Now
Relate News
What is the Difference between High-Frequency Electrocautery and Electrocoagulation?Simply put, it is a surgical knife that generates a high-voltage current at the end of the electric knife pen through the device, which instantly heats the tissue and thus plays a cutting role.For high-frequency electrocautery, the basic functions are electrocautery and electrocoagulation.
Explanation of precautions when using electrosurgical unitElectrosurgical Unit is a device that almost every surgeon will come into contact with. When using it, the following points should be noted:1. Have an understanding of the principles of ESU cutting and coagulation.2. When using a electrosurgical unit, do not select the wrong mode. For example, do not choose the cutting and coagulation modes incorrectly. If you choose the cutting mode during coagulation, it will cause tissue cells to burn and die.3.
Is Oral and Dental Electrosurgical Unit Specialized?Electrosurgical Unit are widely used in general surgery, cosmetic plastic surgery, and various minimally invasive surgeries due to their excellent cutting and coagulation abilities.
What to do if there is no output when the ESU Unit is started and turned on?The ESU Unit has long been widely used as an electrical surgical equipment in surgery. Once there are problems with the ESU Unit during surgery, it will inevitably affect the surgical process.
Common Injuries and Prevention during High-frequency ElectrocauteryPreventive measures for plate burnsChoose a suitable high-frequency electric knife negative electrode plate, install the negative electrode plate correctly, and ensure that the size and area of the plate are appropriate. Ensure that the effective contact area is greater than 100 centimeters. Infants and children are prohibited from using specialized negative electrode plates for cutting and folding. Clean the skin of the bonding area before pasting the negative electrode board to reduce resistance.
Application of Electrosurgical Unit in Oral Tissue Repair      Electrosurgical Unit is the use of high-frequency alternating current technology to generate thermal effects within tissues and selectively destroy certain tissues. The radio frequency energy emitted by the host is concentrated in the electrodes, forming a complete circuit through the human body, reflux plate, and its circuit. According to different usage purposes, energy output can be divided into fully rectified output and partially rectified output.
The Principle and Applicability of Bipolar Electrosurgical UnitHigh frequency surgical unit is divided into monopolar and bipolar. monopolar high-frequency surgical unit forms a circuit between the negative electrode plate and the knife pen. The following introduces the working principle and applicable surgery of bipolar electric knife:The principle of bipolar high-frequency electric knife is to provide high-frequency electrical energy to the body tissue through the two tips of bipolar forceps,causing the blood vessels between the two ends of the bipolar forceps to dehydrate and coag
Electrosurgical Unit for Tonsillectomy InjuryThe tonsils are rich in blood vessels and wounds are prone to bleeding. More and more doctors choose thermal cutting instruments such as plasma, carbon dioxide laser, and ultrasound knife for surgery. Low temperature plasma knife is a highly regarded instrument with a working temperature of only 40-70 ℃, and it also has the functions of cutting, hemostasis, and ablation.
Introduction to Electrosurgical UnitWhat is a ESU?Electrosurgical Unit is widely used in various surgeries, for tissue cutting and coagulation, and is one of the essential equipment in the operating room.What do the parameters of ESU mean?Electrosurgical Units are divided into monopolar and bipolar modes, and in monopolar mode, they must be used together with the negative electrode plate (neutral electrode plate). Let the current released by the blade flow back to the electric knife through the negative electrode plate to form a closed loop, so as not to burn the human body.
How to judge the quality of a Electrosurgical Unit      Electrosurgical Unit has a wide range of applications in surgery. In addition to being widely used in general surgery, brain surgery, chest surgery, facial features, etc., it is also increasingly used in endoscopic minimally invasive surgery. Its advantages are fast cutting speed and coagulation effect.
x

Submitted successfully

We will contact you as soon as possible

Close