Electrosurgical Unit/High-Frequency Electrical Surgical Knife/Electrosurgical Cautery Machine-manufacture,factory,supplier from China

(Total 24 Products for Electrosurgical Unit/High-Frequency Electrical Surgical Knife/Electrosurgical Cautery Machine)
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
  Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasisBLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaponzation of prostatic tissue or any fat tissue.
  Contact Now
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
  Contact Now
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
  Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPure Cut: High-frequency alternating current produces smooth, fast cuts that induce little-understood hemostasis Mix 1: Preset Mix Cut Modes provide surgeons with varying degrees of hemostasis in cut mode. Mix 2: This mode is used for vaporization of prostate tissue or any fatty tissue. Higher output wattage gives rapid tissue cutting effect.
  Contact Now
Product descriptionThe 416KHz (±10%) high frequency current generated by the machine can be used for biological tissue cutting, coagulation and other surgical operations, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; Unipolar solidification: spray solidification, soft solidification and standard bipolar six working modes.
  Contact Now
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, APG type ordinary equipment, powered by 220V±10% network power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues. It has the functions of unipolar pure cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation There are six working modes: , sof
  Contact Now
Product descriptionLigasure is also called high frequency surgical system, and ligasure is widely used in various surgical operations. Compared with traditional electrosurgical equipment, ligasure has the function of cutting blood coagulation and sealing 7 mm large blood vessels.FAQQ1. What is the advantage about your company?A1.The company has been engaged in export business for more than 15 years, with a professional team and professional production line.Q2.
  Contact Now
Product descriptionThe 416KHz (± 10%) high frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut 1, blend cut 2; Monopolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independent and isolated CF type anti-defibrillation application parts (Monopolar and Bipolar), Non-AP、Non-APG type common equipment, and 220V ± 10% or 110V ± 10% network power supply.Technology parameterRated out
  Contact Now
Product descriptionThe 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as biological tissue cutting and coagulation, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independently isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, non-APG type general equipment, 220V±10% or 110V±10% network power supply.Technology parameterRated out
  Contact Now
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type defibrillation-proof application parts (unipolar and bipolar), non-AP, APG-type common equipment, 220V±10% mains power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation on biological tissues.
  Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
  Contact Now
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
  Contact Now
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
  Contact Now
Product DescriptionScope of ApplicationIt is suitable for various surgeries on cutting or coagulation, including general surgery, heart, urology, gynecology, anorectal surgery, orthopedics, thoracic surgery, tumor, etc. It is also used with surgeries of endoscope, hysteroscope, laparoscope, ENT endoscope, etc. The bipolar can be used in the fine surgeries of microsurgery, neurology, ENT and ophthalmology, hand surgery,etc.Product Details●Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
  Contact Now
CM-350A meets the surgeon's needs in the wide range of general procedures and in special ties including Gynecology, Urology, Neurology, Thorasic, plastic and Reconstructive surgery. It has spray coagulation which rivals the best spark gap generators and with minimum cutting effect.
  Contact Now
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
  Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
  Contact Now
Product descriptionRemote fault diagnosis.Human voice alarm function.Full-function automatic power compensation.System has return electrode monitoring (REM) system.Microprocessor control and digital display in LED panel.Used for Monopolar and Bipolar surgery in many surgical fields.Support bipolar closure and separation to meet the requirements of surcical bipolar treatment withoutsticking the negative plate.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.This machine has a power-off protection circuit, which
  Contact Now
Product descriptionThis endoscope camera is equipped with Sony CCD sensors, focusing on high-quality images with a large number of pixels, low noise, and excellent photosensitivity. Its compact design helps users easily carry it for emergency situations or basic OPD use.
  Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
  Contact Now
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
  Contact Now
Product descriptionThe 4K medical endoscope camera system is compatible with multiple professions, including surgical endoscopy, urology, gynecology, orthopedics, and otolaryngology.With the help of 4K technology, we are striving to improve the visibility of endoscopes even better than open surgery by adding features such as ultra-high definition, wider color gamut, and enlarged visualization.Technical Parameter1.TV system: PAL2.
  Contact Now
Product Features1/2.8 Sony CMOS Full HD Image Sensor;Built in 19 inch high-definition display, displaying more tissue details to ensure surgical safety;Integrated design of LED cold light source and camera, saving space and easy to carry;Built-in USB full HD image storage, photo capture/video recording function;IPX8 waterproof camera.Technical ParametersCamera1/2.8inch SONY CMOS HD CameraPixel2100,000 pixelsImage size(Horizontal×Vertical)1920×1080Scanning systemProgressive ScanningFrame rate(1920×1080)60pSNR60dB Tolerance 20%Horizon resolution1080 TVL Tolerance 20%Monitor19 inch HD medica
  Contact Now
Relate News
The Principle and Applicability of Bipolar Electrosurgical UnitHigh frequency surgical unit is divided into monopolar and bipolar. monopolar high-frequency surgical unit forms a circuit between the negative electrode plate and the knife pen. The following introduces the working principle and applicable surgery of bipolar electric knife:The principle of bipolar high-frequency electric knife is to provide high-frequency electrical energy to the body tissue through the two tips of bipolar forceps,causing the blood vessels between the two ends of the bipolar forceps to dehydrate and coag
High Frequency Electric Knife Power DetectionThe power detection methods of various high-frequency electric knife brands are slightly different, but the principles are similar and basically the same. However, it should be noted that the load resistance selected for testing single pole and double pole high-frequency electric knives is generally different.
The Difference between Electrosurgical Unit and Ultrasonic KnifeThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ The mechanical oscillation of m amplitude generates fri
What is the Difference between High-Frequency Electrocautery and Electrocoagulation?Simply put, it is a surgical knife that generates a high-voltage current at the end of the electric knife pen through the device, which instantly heats the tissue and thus plays a cutting role.For high-frequency electrocautery, the basic functions are electrocautery and electrocoagulation.
The Working Mode of Electrosurgical Unit1. Monopolar modeIn the monopole mode of the Electrosurgical Unit, a complete circuit is used to cut and solidify tissue, which consists of a high-frequency generator inside the high-frequency electric knife, patient electrode plates connected to wires, and electrodes. In most applications, current passes through the patient through effective wires and electrodes, and then returns to the generator of the high-frequency electric knife through the patient's electrode plate and connecting wires.2.
Analysis of Polyp Treatment Using Argon Gas Knife under the MicroscopeGastrointestinal polyp carcinogenesis is a common type of digestive disease, and with the promotion of fiberoptic endoscopy, the detection rate of this disease has significantly increased. Clinical diagnosis of polyp cancer is often confirmed through endoscopic resection surgery, but there is no unified conclusion on whether surgical treatment is necessary.
Reasonable Application of Medical High-frequency Electric knife and Argon Plasma ESUMedical high-frequency electric knife and argon plasma ESU have been widely used in both open surgery and endoscopic surgery.Each type of electric knife has its own characteristics, and different electric knives are selected to achieve different surgical effects for different lesions1.Benefits of using medical high-frequency electric knives under endoscopy:Through the endoscope interface, the use of high-frequency electric knife under endoscope has obvious advantages, which can reduce a lot of unnecessary pain.
Application of Electrosurgical Unit in Oral Tissue Repair      Electrosurgical Unit is the use of high-frequency alternating current technology to generate thermal effects within tissues and selectively destroy certain tissues. The radio frequency energy emitted by the host is concentrated in the electrodes, forming a complete circuit through the human body, reflux plate, and its circuit. According to different usage purposes, energy output can be divided into fully rectified output and partially rectified output.
Common Injuries and Prevention during High-frequency ElectrocauteryPreventive measures for plate burnsChoose a suitable high-frequency electric knife negative electrode plate, install the negative electrode plate correctly, and ensure that the size and area of the plate are appropriate. Ensure that the effective contact area is greater than 100 centimeters. Infants and children are prohibited from using specialized negative electrode plates for cutting and folding. Clean the skin of the bonding area before pasting the negative electrode board to reduce resistance.
Introduction to Electrosurgical UnitWhat is a ESU?Electrosurgical Unit is widely used in various surgeries, for tissue cutting and coagulation, and is one of the essential equipment in the operating room.What do the parameters of ESU mean?Electrosurgical Units are divided into monopolar and bipolar modes, and in monopolar mode, they must be used together with the negative electrode plate (neutral electrode plate). Let the current released by the blade flow back to the electric knife through the negative electrode plate to form a closed loop, so as not to burn the human body.