Hydraulic Operating Table-manufacture,factory,supplier from China

(Total 24 Products for Hydraulic Operating Table)
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contact Now
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
Contact Now
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
Contact Now
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
Contact Now
Product DescriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15-year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
Contact Now
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
Contact Now
CM-350A meets the surgeon's needs in the wide range of general procedures and in special ties including Gynecology, Urology, Neurology, Thorasic, plastic and Reconstructive surgery. It has spray coagulation which rivals the best spark gap generators and with minimum cutting effect.
Contact Now
Product descriptionAnaesthesia main unit:High luminance digital LED screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarm: O2 gas pressure is low, alarm time exceeds 7 secondsHigh pressure limit: Whenever the airway pressure exceeds the preset high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Power failure alarming,power extendable functionO2 flush:25~75L/minGas Pressure:O2:0.3~0.5MPaPower:220V±10%, 50Hz±1%Technology specificationFlow meter:O2 - dual tube(0.05~1L/min,1.1~10L/min
Contact Now
Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contact Now
Product descriptionThe smoke evacuator is easy to operate and easy to replace filters.
Contact Now
Product description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations.
Contact Now
IntroductionAnaesthesia main unit:High resolution 5.5''  LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
Contact Now
Product descriptionThe 4K medical endoscope camera system is compatible with multiple professions, including surgical endoscopy, urology, gynecology, orthopedics, and otolaryngology.With the help of 4K technology, we are striving to improve the visibility of endoscopes even better than open surgery by adding features such as ultra-high definition, wider color gamut, and enlarged visualization.Technical Parameter1.TV system: PAL2.
Contact Now
Product Features1/2.8 Sony CMOS Full HD Image Sensor;Built in 19 inch high-definition display, displaying more tissue details to ensure surgical safety;Integrated design of LED cold light source and camera, saving space and easy to carry;Built-in USB full HD image storage, photo capture/video recording function;IPX8 waterproof camera.Technical ParametersCamera1/2.8inch SONY CMOS HD CameraPixel2100,000 pixelsImage size(Horizontal×Vertical)1920×1080Scanning systemProgressive ScanningFrame rate(1920×1080)60pSNR60dB Tolerance 20%Horizon resolution1080 TVL Tolerance 20%Monitor19 inch HD medica
Contact Now
Product descriptionApplied in all fields, such as laparoscopy, urology, rectoscopy, otolaryngology, etc1) It is recommended that all rigid and flexible mirrors can be used for diagnosis and surgery2) Combine Sony CMOS high-definition camera with 80W LED light source.3) Equipped with 22 inch high-definition display4) The integrated design of LED cold light source and camera saves space and is convenient to carry;5) Video recording and capture functionsTechnical specificationProduct ModelYKD-9122Camera1/2.8 inch SONY CMOS HD CameraPixels2,100,000 PixelsImage Size(Horizontal*Vertical)1920*10
Contact Now
Product descriptionThe 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as biological tissue cutting and coagulation, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independently isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, non-APG type general equipment, 220V±10% or 110V±10% network power supply.Technology parameterRated out
Contact Now
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
Contact Now
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
Contact Now
Product descriptionRemote fault diagnosis.Human voice alarm function.Full-function automatic power compensation.System has return electrode monitoring (REM) system.Microprocessor control and digital display in LED panel.Used for Monopolar and Bipolar surgery in many surgical fields.Support bipolar closure and separation to meet the requirements of surcical bipolar treatment withoutsticking the negative plate.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.This machine has a power-off protection circuit, which
Contact Now
Relate News
Argon Plasma ESUTechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeWoking modes comply with Argon Plasma function:a) Pure Cut:1W-300W(Load 500Ω) b)Blend 1:1W-200W(Load 500Ω)c)Blend 2:1W-150W(Load 500Ω)d) ENDO Cut:99%(Load 500Ω)e)Spray Coag.:1W-80W (Load 500Ω)f)Desicate Coag.:1W-120W (Load 500Ω)g) BI-Coag:1W-70W (Load 100Ω) (optional)h)Argon: Dual Argon airflow adjustment,
Render Medical AGSS DeviceAfter the anesthesia gas from the anesthesia machine is inhaled into the human body, the residual gas is discharged into the surrounding environment. Although it may cause pollution to the air in the operating room, this pollution has not been taken seriously, especially in small hospitals. The AGSS anesthesia exhaust gas emission system optional for imported anesthesia machines is expensive and belongs to the consumption type. Due to departmental cost considerations, it is rarely used.
Introduction to Electrosurgical UnitWhat is a ESU?Electrosurgical Unit is widely used in various surgeries, for tissue cutting and coagulation, and is one of the essential equipment in the operating room.What do the parameters of ESU mean?Electrosurgical Units are divided into monopolar and bipolar modes, and in monopolar mode, they must be used together with the negative electrode plate (neutral electrode plate). Let the current released by the blade flow back to the electric knife through the negative electrode plate to form a closed loop, so as not to burn the human body.
CM-350ATechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeOutput modesa) Pure Cut:1W-350W(Max.400W,Load 500Ω) b)Blend 1:1W-250W(Load 500Ω)c)Blend 2:1W-200W(Load 500Ω)d) Blend 3:1W-150W(Load 500Ω)e)ENDO Cut:99%(Load 500Ω)f)Spray Coag.:1W-80W (Load 500Ω)g) Force Coag.:1W-120W (load 500 Ω)h) Desicate Coag.:1W-120W (Load 500Ω)i)BI-Coag:1W-70W (Load 100Ω)j)Auto-Coag.:1W-70W (Load 1
Anesthesia Machine Model40High resolution 8”color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency, Airway pressure, Pressure-time wave,High pressure limitation, Low pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose, semi-close, semi-open systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure limitation: Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection autom
Common Injuries and Prevention during High-frequency ElectrocauteryPreventive measures for plate burnsChoose a suitable high-frequency electric knife negative electrode plate, install the negative electrode plate correctly, and ensure that the size and area of the plate are appropriate. Ensure that the effective contact area is greater than 100 centimeters. Infants and children are prohibited from using specialized negative electrode plates for cutting and folding. Clean the skin of the bonding area before pasting the negative electrode board to reduce resistance.
High Frequency Electric Knife Power DetectionThe power detection methods of various high-frequency electric knife brands are slightly different, but the principles are similar and basically the same. However, it should be noted that the load resistance selected for testing single pole and double pole high-frequency electric knives is generally different.
Analysis of Polyp Treatment Using Argon Gas Knife under the MicroscopeGastrointestinal polyp carcinogenesis is a common type of digestive disease, and with the promotion of fiberoptic endoscopy, the detection rate of this disease has significantly increased. Clinical diagnosis of polyp cancer is often confirmed through endoscopic resection surgery, but there is no unified conclusion on whether surgical treatment is necessary.
The Difference between Electrosurgical Unit and Ultrasonic KnifeThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ The mechanical oscillation of m amplitude generates fri
Reasonable Application of Medical High-frequency Electric knife and Argon Plasma ESUMedical high-frequency electric knife and argon plasma ESU have been widely used in both open surgery and endoscopic surgery.Each type of electric knife has its own characteristics, and different electric knives are selected to achieve different surgical effects for different lesions1.Benefits of using medical high-frequency electric knives under endoscopy:Through the endoscope interface, the use of high-frequency electric knife under endoscope has obvious advantages, which can reduce a lot of unnecessary pain.
x

Submitted successfully

We will contact you as soon as possible

Close