Mobile Operating Light-manufacture,factory,supplier from China

(Total 24 Products for Mobile Operating Light)
Product descriptionA high-brightness lighting device composed of high-power LED and its componentsThis product uses 80W LED as the light source. High luminous efficiency and high illumination.It is designed with a touch switch, brightness display, and electromagnetic compatibility switch power supply.Application: Hysteroscopy, Nasal Endoscopy, OtolaryngologyTechnical ParametersRated input power: 100WOptical output illumination value: >1600000LXLamp rated power: 80WColor temperature: 3000K-7000KColor rendering index: ≥90Lamp working life: ≥40000hTotal light: ≥500LmFAQQ1.
Contact Now
Product descriptionApplied in all fields, such as laparoscopy, urology, rectoscopy, otolaryngology, etc1) It is recommended that all rigid and flexible mirrors can be used for diagnosis and surgery2) Combine Sony CMOS high-definition camera with 80W LED light source.3) Equipped with 22 inch high-definition display4) The integrated design of LED cold light source and camera saves space and is convenient to carry;5) Video recording and capture functionsTechnical specificationProduct ModelYKD-9122Camera1/2.8 inch SONY CMOS HD CameraPixels2,100,000 PixelsImage Size(Horizontal*Vertical)1920*10
Contact Now
Product Features1/2.8 Sony CMOS Full HD Image Sensor;Built in 19 inch high-definition display, displaying more tissue details to ensure surgical safety;Integrated design of LED cold light source and camera, saving space and easy to carry;Built-in USB full HD image storage, photo capture/video recording function;IPX8 waterproof camera.Technical ParametersCamera1/2.8inch SONY CMOS HD CameraPixel2100,000 pixelsImage size(Horizontal×Vertical)1920×1080Scanning systemProgressive ScanningFrame rate(1920×1080)60pSNR60dB Tolerance 20%Horizon resolution1080 TVL Tolerance 20%Monitor19 inch HD medica
Contact Now
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
Contact Now
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
Contact Now
Product DescriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15-year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contact Now
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
Contact Now
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contact Now
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
Contact Now
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
Contact Now
Product descriptionThe 4K medical endoscope camera system is compatible with multiple professions, including surgical endoscopy, urology, gynecology, orthopedics, and otolaryngology.With the help of 4K technology, we are striving to improve the visibility of endoscopes even better than open surgery by adding features such as ultra-high definition, wider color gamut, and enlarged visualization.Technical Parameter1.TV system: PAL2.
Contact Now
IntroductionAnaesthesia main unit:High resolution 5.5''  LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
Contact Now
Product descriptionThe anesthesia evaporator combines the characteristics of ergonomics, accuracy, safety, and reliability. Precision design will provide reliable and safe solutions for the filling and installation types of anesthesia machines.Adopting the latest innovative design of the conveying system, the vaporizer can deliver accurate concentrations under different flow rates, pressures, temperatures, and other conditions.The carburetor is calibrated by skilled technicians.
Contact Now
Product Description1. 7" screen displays information area, alarm area, monitoring area, and setting area. 2. High precision mechanical flowmeter, instantly know the fresh gas flow to animals. 3. Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime. 4. Real time pressure-time, flow-time oscillogram 5. Manual and mechanical ventilation for safer operation.6. External sensor design makes parameters setting more accurate. 7.
Contact Now
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
Contact Now
Product descriptionThis endoscope camera is equipped with Sony CCD sensors, focusing on high-quality images with a large number of pixels, low noise, and excellent photosensitivity. Its compact design helps users easily carry it for emergency situations or basic OPD use.
Contact Now
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, APG type ordinary equipment, powered by 220V±10% network power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues. It has the functions of unipolar pure cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation There are six working modes: , sof
Contact Now
Product descriptionThe 416KHz (±10%) high frequency current generated by the machine can be used for biological tissue cutting, coagulation and other surgical operations, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; Unipolar solidification: spray solidification, soft solidification and standard bipolar six working modes.
Contact Now
Product descriptionLigasure is also called high frequency surgical system, and ligasure is widely used in various surgical operations. Compared with traditional electrosurgical equipment, ligasure has the function of cutting blood coagulation and sealing 7 mm large blood vessels.FAQQ1. What is the advantage about your company?A1.The company has been engaged in export business for more than 15 years, with a professional team and professional production line.Q2.
Contact Now
Product descriptionAnaesthesia main unit:High luminance digital LED screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarm: O2 gas pressure is low, alarm time exceeds 7 secondsHigh pressure limit: Whenever the airway pressure exceeds the preset high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Power failure alarming,power extendable functionO2 flush:25~75L/minGas Pressure:O2:0.3~0.5MPaPower:220V±10%, 50Hz±1%Technology specificationFlow meter:O2 - dual tube(0.05~1L/min,1.1~10L/min
Contact Now
Relate News
Characteristics of Emergency Transport Ventilator      Many people believe that emergency transport ventilators are equivalent to simple ventilators, because compared to professional ICU therapeutic ventilators, emergency transport ventilators do not have as many ventilation modes and parameter monitoring in terms of mode function. However, in fact, professional emergency transport ventilators should have the following major characteristics (which cannot be achieved by large ICU ventilators):       Portability:1. Small in size and light in weight.
Render Medical AGSS DeviceAfter the anesthesia gas from the anesthesia machine is inhaled into the human body, the residual gas is discharged into the surrounding environment. Although it may cause pollution to the air in the operating room, this pollution has not been taken seriously, especially in small hospitals. The AGSS anesthesia exhaust gas emission system optional for imported anesthesia machines is expensive and belongs to the consumption type. Due to departmental cost considerations, it is rarely used.
Introduction to Electrosurgical UnitWhat is a ESU?Electrosurgical Unit is widely used in various surgeries, for tissue cutting and coagulation, and is one of the essential equipment in the operating room.What do the parameters of ESU mean?Electrosurgical Units are divided into monopolar and bipolar modes, and in monopolar mode, they must be used together with the negative electrode plate (neutral electrode plate). Let the current released by the blade flow back to the electric knife through the negative electrode plate to form a closed loop, so as not to burn the human body.
Argon Plasma ESUTechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeWoking modes comply with Argon Plasma function:a) Pure Cut:1W-300W(Load 500Ω) b)Blend 1:1W-200W(Load 500Ω)c)Blend 2:1W-150W(Load 500Ω)d) ENDO Cut:99%(Load 500Ω)e)Spray Coag.:1W-80W (Load 500Ω)f)Desicate Coag.:1W-120W (Load 500Ω)g) BI-Coag:1W-70W (Load 100Ω) (optional)h)Argon: Dual Argon airflow adjustment,
CM-350ATechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeOutput modesa) Pure Cut:1W-350W(Max.400W,Load 500Ω) b)Blend 1:1W-250W(Load 500Ω)c)Blend 2:1W-200W(Load 500Ω)d) Blend 3:1W-150W(Load 500Ω)e)ENDO Cut:99%(Load 500Ω)f)Spray Coag.:1W-80W (Load 500Ω)g) Force Coag.:1W-120W (load 500 Ω)h) Desicate Coag.:1W-120W (Load 500Ω)i)BI-Coag:1W-70W (Load 100Ω)j)Auto-Coag.:1W-70W (Load 1
Anesthesia Machine Model40High resolution 8”color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency, Airway pressure, Pressure-time wave,High pressure limitation, Low pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose, semi-close, semi-open systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure limitation: Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection autom
The Working Mode of Electrosurgical Unit1. Monopolar modeIn the monopole mode of the Electrosurgical Unit, a complete circuit is used to cut and solidify tissue, which consists of a high-frequency generator inside the high-frequency electric knife, patient electrode plates connected to wires, and electrodes. In most applications, current passes through the patient through effective wires and electrodes, and then returns to the generator of the high-frequency electric knife through the patient's electrode plate and connecting wires.2.
Introduction to Anesthesia Machine Evaporator      The anesthesia evaporator is an important component of the anesthesia machine, and its quality not only indicates the level of the anesthesia machine, but also relates to the success or failure of inhalation anesthesia, directly affecting the safety of the patient.
Anesthesia Machine EvaporatorThe Function of Evaporator Anesthesia machine evaporation tank, also known as evaporator, is generally divided into several types: enflurane, isoflurane, halothane, sevoflurane, desflurane, etc. The commonly used ones in China are enflurane tanks, isoflurane tanks, and sevoflurane, and the use of enflurane has been banned domestically. Its function is to convert liquid inhaled anesthetics into gas, and then mix them with oxygen to a certain proportion concentration before delivering them to the patient.