Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contact Now
Product description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations.
Contact Now
Product DescriptionVeterinary anesthesia systems are widely used in veterinary clinics, hospitals and laboratories and continue to be well received by customers around the world.The SD-M2000A(P) model is designed for safe, simple, and controlled inhalation anesthesia in animals. Veterinary anesthesia systems provide rapid control of depth of anesthesia, low respiratory resistance, acuity from high to low, simple to complex cases, small to large animals such as dogs, cats, rabbits, mice, birds, etc.Technical SpecificationAnaesthesia main unit:Working Mode: ManualWorking method: Close,
Contact Now
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contact Now
Product descriptionSD-M2000A(P) Veterinary anesthesia machines are reliable professional equipment for small animal anesthesia. Easy installation and maintenance, saving space.
Contact Now
Product DescriptionScope of ApplicationIt is suitable for various surgeries on cutting or coagulation, including general surgery, heart, urology, gynecology, anorectal surgery, orthopedics, thoracic surgery, tumor, etc. It is also used with surgeries of endoscope, hysteroscope, laparoscope, ENT endoscope, etc. The bipolar can be used in the fine surgeries of microsurgery, neurology, ENT and ophthalmology, hand surgery,etc.Product Details●Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
Contact Now
Product description This transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contact Now
Product descriptionThe smoke evacuator is easy to operate and easy to replace filters.
Contact Now
Product descriptionAnaesthesia main unit:High luminance digital LED screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarm: O2 gas pressure is low, alarm time exceeds 7 secondsHigh pressure limit: Whenever the airway pressure exceeds the preset high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Power failure alarming,power extendable functionO2 flush:25~75L/minGas Pressure:O2:0.3~0.5MPaPower:220V±10%, 50Hz±1%Technology specificationFlow meter:O2 - dual tube(0.05~1L/min,1.1~10L/min
Contact Now
Product descriptionApplied in all fields, such as laparoscopy, urology, rectoscopy, otolaryngology, etc1) It is recommended that all rigid and flexible mirrors can be used for diagnosis and surgery2) Combine Sony CMOS high-definition camera with 80W LED light source.3) Equipped with 22 inch high-definition display4) The integrated design of LED cold light source and camera saves space and is convenient to carry;5) Video recording and capture functionsTechnical specificationProduct ModelYKD-9122Camera1/2.8 inch SONY CMOS HD CameraPixels2,100,000 PixelsImage Size(Horizontal*Vertical)1920*10
Contact Now
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
Contact Now
CM-350A meets the surgeon's needs in the wide range of general procedures and in special ties including Gynecology, Urology, Neurology, Thorasic, plastic and Reconstructive surgery. It has spray coagulation which rivals the best spark gap generators and with minimum cutting effect.
Contact Now
Product Description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations. During first aid and transport, even in the event of a power outage, it can help patients maintain normal respiratory function and prevent dangerous situationscaused by insufficient oxygen.FAQQ1.What are your packaging details?A1.
Contact Now
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPure Cut: High-frequency alternating current produces smooth, fast cuts that induce little-understood hemostasis Mix 1: Preset Mix Cut Modes provide surgeons with varying degrees of hemostasis in cut mode. Mix 2: This mode is used for vaporization of prostate tissue or any fatty tissue. Higher output wattage gives rapid tissue cutting effect.
Contact Now
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
Contact Now
Product descriptionLigasure is also called high frequency surgical system, and ligasure is widely used in various surgical operations. Compared with traditional electrosurgical equipment, ligasure has the function of cutting blood coagulation and sealing 7 mm large blood vessels.FAQQ1. What is the advantage about your company?A1.The company has been engaged in export business for more than 15 years, with a professional team and professional production line.Q2.
Contact Now
Product descriptionThe 4K medical endoscope camera system is compatible with multiple professions, including surgical endoscopy, urology, gynecology, orthopedics, and otolaryngology.With the help of 4K technology, we are striving to improve the visibility of endoscopes even better than open surgery by adding features such as ultra-high definition, wider color gamut, and enlarged visualization.Technical Parameter1.TV system: PAL2.
Contact Now
Product Features1/2.8 Sony CMOS Full HD Image Sensor;Built in 19 inch high-definition display, displaying more tissue details to ensure surgical safety;Integrated design of LED cold light source and camera, saving space and easy to carry;Built-in USB full HD image storage, photo capture/video recording function;IPX8 waterproof camera.Technical ParametersCamera1/2.8inch SONY CMOS HD CameraPixel2100,000 pixelsImage size(Horizontal×Vertical)1920×1080Scanning systemProgressive ScanningFrame rate(1920×1080)60pSNR60dB Tolerance 20%Horizon resolution1080 TVL Tolerance 20%Monitor19 inch HD medica
Contact Now
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
Contact Now
IntroductionAnaesthesia main unit:High resolution 5.5'' LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
Contact Now
Product descriptionA high-brightness lighting device composed of high-power LED and its componentsThis product uses 80W LED as the light source. High luminous efficiency and high illumination.It is designed with a touch switch, brightness display, and electromagnetic compatibility switch power supply.Application: Hysteroscopy, Nasal Endoscopy, OtolaryngologyTechnical ParametersRated input power: 100WOptical output illumination value: >1600000LXLamp rated power: 80WColor temperature: 3000K-7000KColor rendering index: ≥90Lamp working life: ≥40000hTotal light: ≥500LmFAQQ1.
Contact Now
Product descriptionThe anesthesia evaporator combines the characteristics of ergonomics, accuracy, safety, and reliability. Precision design will provide reliable and safe solutions for the filling and installation types of anesthesia machines.Adopting the latest innovative design of the conveying system, the vaporizer can deliver accurate concentrations under different flow rates, pressures, temperatures, and other conditions.The carburetor is calibrated by skilled technicians.
Contact Now
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
Contact Now
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contact Now