Endotherm Knife
Product advantages
The high-frequency generator has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope, laparoscope and other endoscopes.
Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate.
Patient circuit bipolar electrode plate contact quality detection system.
Monopolar output can be controlled either by hand or foot, and monopolar/bipolar automatic output.
This machine has a power-off protection circuit, which can memorize the output set value of each function in real time.
Remote fault diagnosis.
Human voice alarm function
Passed EMC test.
Product description
The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as biological tissue cutting and coagulation, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.
The output of this machine is fully suspended, with two independently isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, non-APG type general equipment, 220V±10% or 110V±10% network power supply.
Technology parameter
Rated output power:
Pure cutting: 1W~350W (maximum 400W, load 500Ω);
High-frequency alternating current produces smooth, fast cuts that cause little or no hemostasis. (Focusless precision cutting, 100% cutting.)
Hybrid cutting 1: 1W~250W (load 500Ω);
Preset hybrid cutting modes provide surgeons with varying degrees of hemostasis in cutting modes. (Shallow focus gamma precision cutting is 80% cut, 20% solid.)
Hybrid cutting 2: 1W~200W (load 500Ω);
This mode is used for vaporization of prostate tissue or any fatty tissue. Higher output power enables fast tissue cutting results. (60% cut, 40% set.)
Endu Cut: 99% (load 500Ω);
This mode is used to automatically control the cutting system and reduces the complication rate of endoscopic sphincterotomy (EST) and the incidence of serum hyperamylaseemia after EST compared with the traditional hybrid cutting mode.
Spray solidification: 1W~80W (load 500Ω);
The spray output is used to coagulate directly onto tissue via spark. The sparks above will not produce any cutting effect due to their high crest factor. (lots of solidification)
Drying and solidification: 1W~120W (load 500Ω);
Coagulation where the active electrode is in direct contact with tissue is called desiccation and is the type of coagulation used in most surgeries to ensure precise drying while reducing damage to surrounding tissue.
Standard bipolar electrocoagulation: 1W~70W (load 100Ω);
BI-COAG - for highly precise control of the coagulation process and elimination of carbonation.
Machine power consumption: ≤1100VA. (Cutting function 350W);
Normal operation
Ambient temperature range: 5℃~40℃;
Relative humidity range: ≤80%;
Atmospheric pressure range: 86.0~106.0kPa;
Power supply: 220V±10%, 50±1Hz; or 110V±10%, 60±1Hz
Working frequency: 416kHz;
transportation and storage
Ambient temperature range: - 40℃~55℃;
Relative humidity range: ≤95%;
Atmospheric pressure range: 50.0~106.0kPa.