High Frequency Surgical Unit

Product advantages:

Human voice alarm function.

Support in underwater cut operation.

Full-function automatic power compensation.

System has return electrode monitoring (REM) system.

Microprocessor control and digital displav in LED panel.

Used for Monopolar and Bipolar surgery in many surgical fields.

Patient circuit bipolar electrode plate contact quality detection system.

Fully suspended power supply is not affected by unstable power supply.

This machine has a power-off protection circuit, which can memorize the output set value of each function in real time.

Double-hand piece outout can meet the needs of more separate operations such as cardiac bypass,anorectal and so on.

Output 10 groups of memory modes, support endoscopic treatment, ESD, ERCP, polypectomy and other operations.

Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate.

System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,

aparoscope and other endoscopes.

Monopolar outout can be controled either bv hand or foot, and monopolar/bipolar automatic outpout.

The three-foot pedal independently controls the direct step output without conversion.

Contact Now E-Mail Telephone
Product Details

Product description

Applicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etc

CUT MODE

PURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasisBLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaponzation of prostatic tissue or any fat tissue. The higher output wattage gives fast cuting effect of the tissueBLEND 3:It is used for major coagulation in major surgery, with some cutting functions

ENDO CUT

The mode is used to automatically controlled cut system to reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyper-mylasemia after EST compared to the conventional blended cut mode

COAG MODE

SPRAY:

Spray output is used to coagulate directly onto tissue with sparks. The spark above will not produce any cutting effect because of its high crest factor.

FORCCE:

This mode is greater degree of homeostasis and covers all demands of standard coaqulation. This produce the fine attune waveform that creates superfical resistance in the tissue resulting in superior coagulation, where the tissue destroyed by hyper evaporationThis give surgeons the ability to remove surface structures without damaging deeper or peripheral tissues and to cauterize largesurface areas quickly when required.

DESICATE:

Coagulation in which the active electrode is in direct contact with the tissue is called desiccation and is the type of coagulation used in most surgeries to ensure precise drying while reducing damage to surrounding tissue

BIPOLAR & SEAL

BI-COAG:For highly precise control over coagulation process and privations of carbonization

BI-CUT:This bipolar cut technoloay nearly eliminate excessive current even during precision cutting in minute tissue structureAUTO:Coagulation start by pressing the footswitch and stops output and audio signal automatically when the tissue is coagulatedSEAL Mode: Provides unique combination of pressure & energy to create vessel fussion, leaving no foreign material behind.


CM-350A High Frequency Surgical UnitCM-350A High Frequency Surgical Unit


Technical Parameters

a)Ambient temperature range: 5℃~40℃

b) Relative humidity range: ≤80;

cAtmospheric pressure range: 86.0~106.0kpa;

d) Power supply: 220V+22V, 50Hz+1 or 110V+11V, 60Hz+1;

e) Working frequency: 416kHz

f) Rated power: ≤1100VA (cut-off function 350W)n

g) Type: CF, NonAP, Non-APG type

Output modes:

a) Pure Cut:1W-350W (Max.400W,Load 500Ω)

b) Blend 1:1W-250W(Load 500Ω)

c) Blend 2:1W-200W(Load 500Ω)

d)Blend 3: 1W-150W(Load 500Ω) 

e) ENDO Cut: 99% (Load 500Ω)

f)Spray Coag: 1W-80W (Load 500Ω)

g) Force Coag..1W-120W (load 500Ω)

h) Desicate Coag.:1W-120W (Load 500Ω)

i)BI-Coag.:1W-70W (Load 100Ω)

j)Auto-Coag:1W-70W (Load 100Ω)

k) Bl-Cut:1W-120W(Load 100Ω)

l)SEAL:1W-120W(Load 100Ω)


CM-350A High Frequency Surgical UnitCM-350A High Frequency Surgical Unit


Transportation and Storage:

Dimensions: 490mm (L) x 400mm (W) x 155mm (H)

Weight: Net weight 10kg, gross weight 12kg

Packing size: 51*46*32 cm

Optional trolley Trolley size: 600*450*880mm Weight: Net weight: 12KGS Gross weight: 15KGS

Packing size: 62*63*95 cm


CM-350A High Frequency Surgical Unit


FAQ

Q1.The logo and the color can be customized?

A1.Yes, we welcome you to sample custom.

Q2. What about the delivery time?

A2.We have some material in stock, which can make sure to delivery the goods out quickly for small quantity orders. For customized orders, the delivery time is usually within 15 working days after receiving the payment.

Q3. Can you sell spare parts ?

A3. Yes, Of course .we can sell spare parts to you.

Leave your messages

Related Products

Related News

Popular products

x

Submitted successfully

We will contact you as soon as possible

Close